covar¶
-
sherpa.astro.ui.
covar
(*args)¶ Estimate the confidence intervals for parameters using the covariance method.
The covar command computes confidence interval bounds for the specified model parameters in the dataset, using the covariance matrix of the statistic. The get_covar and set_covar_opt commands can be used to configure the error analysis; an example being changing the
sigma
field to 1.6 (i.e. 90%) from its default value of 1. The output from the routine is displayed on screen, and the get_covar_results routine can be used to retrieve the results.Parameters: - id (str or int, optional) –
- otherids (list of str or int, optional) – The id and otherids arguments determine which data set or data sets are used. If not given, all data sets which have a defined source model are used.
- parameters (optional) – The default is to calculate the confidence limits on all
thawed parameters of the model, or models, for all the
data sets. The evaluation can be restricted by listing
the parameters to use. Note that each parameter should be
given as a separate argument, rather than as a list.
For example
covar(g1.ampl, g1.sigma)
.
See also
covar()
- Estimate the confidence intervals using the confidence method.
get_covar()
- Return the covariance estimation object.
get_covar_results()
- Return the results of the last covar run.
int_proj()
- Plot the statisitic value as a single parameter is varied.
int_unc()
- Plot the statisitic value as a single parameter is varied.
reg_proj()
- Plot the statistic value as two parameters are varied.
reg_unc()
- Plot the statistic value as two parameters are varied.
set_covar_opt()
- Set an option of the covar estimation object.
Notes
The function does not follow the normal Python standards for parameter use, since it is designed for easy interactive use. When called with multiple
ids
orparameters
values, the order is unimportant, since any argument that is not defined as a model parameter is assumed to be a data id.The covar command is different to conf, in that in that all other thawed parameters are fixed, rather than being allowed to float to new best-fit values. While conf is more general (e.g. allowing the user to examine the parameter space away from the best-fit point), it is in the strictest sense no more accurate than covar for determining confidence intervals.
An estimated confidence interval is accurate if and only if:
- the chi^2 or logL surface in parameter space is approximately shaped like a multi-dimensional paraboloid, and
- the best-fit point is sufficiently far from parameter space boundaries.
One may determine if these conditions hold, for example, by plotting the fit statistic as a function of each parameter’s values (the curve should approximate a parabola) and by examining contour plots of the fit statistics made by varying the values of two parameters at a time (the contours should be elliptical, and parameter space boundaries should be no closer than approximately 3 sigma from the best-fit point). The int_proj and reg_proj commands may be used for this.
If either of the conditions given above does not hold, then the output from covar may be meaningless except to give an idea of the scale of the confidence intervals. To accurately determine the confidence intervals, one would have to reparameterize the model, use Monte Carlo simulations, or Bayesian methods.
As covar estimates intervals for each parameter independently, the relationship between sigma and the change in statistic value delta_S can be particularly simple: sigma = the square root of delta_S for statistics sampled from the chi-square distribution and for the Cash statistic, and is approximately equal to the square root of (2 * delta_S) for fits based on the general log-likelihood. The default setting is to calculate the one-sigma interval, which can be changed with the
sigma
option to set_covar_opt or get_covar.Examples
Evaluate confidence intervals for all thawed parameters in all data sets with an associated source model. The results are then stored in the variable
res
.>>> covar() >>> res = get_covar_results()
Only evaluate the parametes associated with data set 2.
>>> covar(2)
Only evaluate the intervals for the
pos.xpos
andpos.ypos
parameters:>>> covar(pos.xpos, pos.ypos)
Change the limits to be 1.6 sigma (90%) rather than the default 1 sigma.
>>> get_covar().sigma = 1.6 >>> covar()
Only evaluate the
clus.kt
parameter for the data sets with identifiers “obs1”, “obs5”, and “obs6”. This will still use the 1.6 sigma setting from the previous run.>>> covar("obs1", ["obs5","obs6"], clus.kt)