In-flight calibrations All calibration will be carried out for FRD-A
and FRD-B (mode 1 and 2). Targets for calibration include:
- 1.
- Crab Nebula -
45 points covering the detector area in a "serpent"-shape with 100
sec observation per point plus 5 minutes for s/c maneuver.
Expected Time Duration: 4 hours
Aim: efficiency calibration
Data Expected: 45-50 Mbyte
- 2.
- Point Source of the order 50 mCrab (type TBD)
45 pointings covering the detector in a "serpent"-shape for 100
sec observation per point plus 5 minutes for s/c maneuver.
Time Duration: 4 hours
Aim: PSF calibration
Data Expected: 10-15 Mbyte
- 3.
- Source of the order 50 mCrab (type LMC, SMC)
Time Duration: 4 hours
Aim: efficiency calibration
Data Expected: 10-15 Mbyte
- 4.
- Source of the order 2 mCrab (type 3C273, 3C390.3, M82)
Time Duration: 4 hours
Aim: efficiency calibration
Data Collected Amount: 1-2 Mbyte
- 5.
- Field without known sources
Time Duration: 4 hours
Aim: efficiency calibration and background determination
Data Collected Amount: 1-2 Mbyte
- 6.
- Out of the focus
Time Duration: 4 hours
Aim: background determination
Data Collected Amount: 1-2 Mbyte
Other Instrument: nearest DSRI Detector (for FRD-A)