Source count rates in HEPC/LEPC can be estimated using HEASARC's
multi-mission simulator PIMMS. It is assumed that a spectral model and
either an absolute flux or a count rate in another instrument are
known. The following dialog illustrates the use of PIMMS to estimate
the HEPC/LEPC rate for a source with a 107.4 K Raymond-Smith
spectrum, cosmic abundances,
cm-2, and a
0.5-2.0 keV flux, at the detector, of
erg cm-2 s-1.
sxg-95: pimms
*** PIMMS version 2.3 ***
1996 Jun 03 release
(this version does not simulate images)
Reading mission directory, please wait
* Current model is BREMSSTRAHLUNG, kT= 10.0000 keV; NH = 1.000E+21
<--- Use 'MODEL' command to change
* By default, input rate is taken to be
Flux ( 2.000- 10.000 keV) in ergs/cm/cm/s
<--- Use 'FROM' command to change the default
* Simulation product will be
Count rate in ASCA SIS ( 0.000- 0.000 keV)
<--- Use 'INSTRUMENT' command to switch to another instrument
PIMMS > from flux erg 0.5-2.0
PIMMS > model rs 2.165 3.0e20
PIMMS > instrument sxg lepc low
PIMMS > go 9.0e-14
* For Raymond Smith model with kT= 2.1645 keV (logT=7.4); NH = 3.000E+20
and a flux ( 0.500- 2.000keV) of 9.000E-14 ergs/cm/cm/s
(Model normalization = 2.743E-03)
* PIMMS predicts 3.003E-02 cps with SXG LEPC LOW
PIMMS > instrument sxg hepc
PIMMS > go 9.0e-14
* For Raymond Smith model with kT= 2.1645 keV (logT=7.4); NH = 3.000E+20
and a flux ( 0.500- 2.000keV) of 9.000E-14 ergs/cm/cm/s
(Model normalization = 2.743E-03)
* PIMMS predicts 6.162E-03 cps with SXG HEPC
PIMMS > quit
sxg-96:
In Figures
- 32, we provide
count rate conversion factors
from ASCA and ROSAT rates, for power law, bremsstrahlung, and
black body spectra, and a range of spectral parameters.
PIMMS may be obtained from the software/tools directory in the anonymous ftp node legacy.gsfc.nasa.gov. Version 2.0 includes support for SXG instruments. To update earlier versions, users may obtain new mission lists and SXG area files from the directory /pub/sxg/pimms in the anonymous ftp node sao-ftp.harvard.edu.