Efficiency. Relative from one energy to another, 3%, Absolute efficiency 10%.
|
SNR plasma T to 5% accuracy and ionization age to 10% requires 3% relative calibration of efficiency.
|
= 0 arcmin,
= 0 arcmin,
= 0°; two off-axis angles, TBD
|
0
|
7 energies from 0.4 to 8 keV: Ti L , Ni L , Na K , Al K , Ti K , Fe K , Cu K .
|
9.1.1
(200x3+2x900)x7+6x900 = 21000 = 5.8 hr
|
ACIS-G, BND(FPCs, SSS), FMS
|
|
Point Spread Function, vs. focus to 10-3peak.
|
Measure 200 km s-1 doppler broadening with signal-to-noise ratio >3.
|
0, x1, x2
|
3 energies (TBD) from 0.4 to 8 keV.
|
9.1.2
((4000x3+2x900)x3+2x900)x3+2x900 = 36.5 hr
|
|
Accuracy: 1% in 1000 resolution elements.
|
Molecular contamination search
|
N.A.
|
|
|
9.2.1
22.2 hr
|
ACIS-G, BND(FPCs, SSS), FMS
|